On 11/03/2013 11:26 AM, Nicolae L. Aldea wrote:
I have some EXAFS measurements on PtO/ metaloxides (supported platinum oxides) but I do not PtO as standard sample for local structure determination. If there are people that have this standard(s) please send me.
Nicolae, I found the attached in the Lytle database. I have no idea as to its provenance or quality. I have no idea how the sample was prepared or where the sample was measured (presumably at Stanford). The header states that the data are PtO at room temperature. Use this with caution! The attached file has converted the quirky file from the Lytle database into something a bit less weird. Energy is the first column, mu(E) is the second column. B -- Bruce Ravel ------------------------------------ bravel@bnl.gov National Institute of Standards and Technology Synchrotron Science Group at NSLS --- Beamlines U7A, X24A, X23A2 Building 535A Upton NY, 11973 Homepage: http://xafs.org/BruceRavel Software: https://github.com/bruceravel