Dear All, Here's an issue I recently encountered while trying to handle some very large in situ datasets in Athena; it may be by design/an inherent limitation, rather than a bug, though: (I am running Demeter 0.9.21 pre and Demeter 0.9.20 , both x64 on Windows 8.1 x64 on separate machines). Each of my datafiles contains over 300 columns of u(E) data as space delimited plain text, however when I try and import them to Athena the import window will only display checkboxes up to column 87. I've attached an example datafile and a logfile to this email. (The data is very poor, but that shouldn't be an issue for debugging...) I've also attached a copy of the datafile as it came from the beamline - this also displays the issue, so it's nothing I've done to the file. On a related note, is it possible for the energy dispersive data calibration to be added back to Athena? To get the calibration parameters for this data I had to use the (very) old version! Thanks, Ian ---- Ian Godfrey PhD Student, UCL/JAIST Programme Industrial Doctorate Centre in Molecular Modelling and Materials Science, Department of Chemistry, University College London and School of Materials Science, Japan Advanced Institute of Science and Technology i.godfrey@ucl.ac.ukmailto:i.godfrey@ucl.ac.uk i.godfrey@jaist.ac.jpmailto:i.godfrey@jaist.ac.jp