Dear All,

 

Here’s an issue I recently encountered while trying to handle some very large in situ datasets in Athena; it may be by design/an inherent limitation, rather than a bug, though:

 

(I am running Demeter 0.9.21 pre and Demeter 0.9.20 , both x64 on Windows 8.1 x64 on separate machines).

 

Each of my datafiles contains over 300 columns of u(E) data as space delimited plain text, however when I try and import them to Athena the import window will only display checkboxes up to column 87.

 

I’ve attached an example datafile and a logfile to this email. (The data is very poor, but that shouldn’t be an issue for debugging…) I’ve also attached a copy of the datafile as it came from the beamline – this also displays the issue, so it’s nothing I’ve done to the file.

 

On a related note, is it possible for the energy dispersive data calibration to be added back to Athena? To get the calibration parameters for this data I had to use the (very) old version!

 

Thanks,

 

Ian

 

----

Ian Godfrey

 

PhD Student,

UCL/JAIST Programme

 

Industrial Doctorate Centre in Molecular Modelling and Materials Science,

Department of Chemistry,

University College London

 

and

 

School of Materials Science,

Japan Advanced Institute of Science and Technology

 

i.godfrey@ucl.ac.uk i.godfrey@jaist.ac.jp