On Thursday, March 07, 2013 12:10:26 PM Bajamundi Cyril wrote:
1. Is this procedure valid? In the sense that no information or features of the spectrum are lost from merge.xmu to merged.xmu.mnor file.
Do you have some reason to believe that might be happening? If so, perhaps you could ask a more explicit question.
2. How will the procedure <Calibrate data> affect this procedure?
Calibration, as it is defined in Athena, is a procedure that changes *both* the E0 and the Eshift values so that a selected point in the spectrum has a selected energy value. http://bruceravel.github.com/demeter/aug/process/cal.html I'm not certain I've answered your question, but I am unclear what is motivating your question. B -- Bruce Ravel ------------------------------------ bravel at bnl.gov National Institute of Standards and Technology Synchrotron Methods Group at NSLS --- Beamlines U7A, X24A, X23A2 Building 535A Upton NY, 11973 My homepage: http://xafs.org/BruceRavel EXAFS software: http://cars9.uchicago.edu/ifeffit/Demeter