Hi Anatoly,
I've checked with other software and the shift is not present. You can also
tell the shift has some other origin by choosing to show data points in the
preferences. This way you can see the data points do not match in energy,
as one might expect for data and a reference. This can also been seen by
looking at the beginning and ending of the spectra, which begin and end at
different energy. Also, note the energy shift parameter for both groups is
set to zero.
Thank you,
George
On Fri, Mar 8, 2013 at 9:25 PM, Anatoly I Frenkel
Maybe the shift is real due to chemical shift of the sample relative to reference material?
Sent from my mobile phone, please forgive typos
----- Reply message ----- From: "George Sterbinsky"
To: "XAFS Analysis using Ifeffit" Subject: [Ifeffit] Shifted data in Athena Date: Fri, Mar 8, 2013 9:15 PM Hello,
I have attached an (D)Athena project with containing two groups, imported as a primary data set and a reference. The groups were therefore imported on the same energy grid. However, when plotted, the energy values of the data points for the two groups are clearly shifted with respect to each other. Can someone please explain the origin of this shift?
Thank you, George
_______________________________________________ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit