Hello Neil, I guess you might have tried this already - do you have any signatures in the I0 data? Such as a glitch or any other edge absorption. Sometimes these can be used as “internal calibration”. -Riti Sarangi
On Jul 12, 2016, at 2:54 PM, Neil M Schweitzer
wrote: Hello, Long time follower/user and first time subscriber! I work at Northwestern University, and one of the services I provide is analyzing XAS data for users who collect data at APS. Generally, I am not at APS to help them collect spectra, I help analyze the data afterwards. A user came to me recently with some Ce L3 data that does not have reference foil data. If I am trying to compare the EXAFS of several different samples (all which should be similar oxidation state, and of which I have other references of similar oxidation state). Does anyone have a suggestion how to work up the data if I can’t calibrate it?
------ Neil M. Schweitzer, Ph.D Operations Director, CleanCat Core Facility Research Assistant Professor Chemical and Biological Engineering Northwestern University 2137 Sheridan Road Evanston, IL 60208-3000 Office: 847-491-2955 http://cleancat.northwestern.edu http://cleancat.northwestern.edu/
_______________________________________________ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov mailto:Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit http://millenia.cars.aps.anl.gov/mailman/options/ifeffit