On Thursday 29 July 2004 07:48 am, SCHLEGEL Michel 177447 wrote:
I ran a test fit in q-space with four spectra and Artemis 0.7.008. It seems that the fitting stage is performed well, and the fitting results in the q-space are even displayed in the Graphics windows. Trouble seems to arise when Artemis tries to write the log file. The 'Artemis palettes' windows doesn't appear on the screen.
Thanks for the report, Michel. This is indeed a problem. A multiple data set fit in q space will not run to completion due to a bug in Artemis 0.7.008 (*not* in Ifeffit). You can run multiple-data set fits in k- or R-space and single data set fits in all three spaces without trouble. The fix will be in the next bug-fix update of the stable branch. Thanks, B -- Bruce Ravel ----------------------------------- ravel@phys.washington.edu Code 6134, Building 3, Room 405 Naval Research Laboratory phone: (1) 202 767 2268 Washington DC 20375, USA fax: (1) 202 767 4642 NRL Synchrotron Radiation Consortium (NRL-SRC) Beamlines X11a, X11b, X23b National Synchrotron Light Source Brookhaven National Laboratory, Upton, NY 11973 My homepage: http://feff.phys.washington.edu/~ravel EXAFS software: http://feff.phys.washington.edu/~ravel/software/exafs/