Peng's question is so common on our mailing list that I would like to write a section of the Artemis document addressing it. At heart, there are two issues. The more important is that N is very highly correlated with S02 (and other things!). The operational issue is the choice I made about only allowing numbers in the N box in Artemis. I would like some suggestions for literature references on the more important part of this question. Specifically, I'd like to know what references all of you cite on the topics of this high correlation and of solving the problem for real measurements. With this bounty, I'll write up a section of the document which we can use when this question comes up in the future. Thanks, B On 07/26/2014 12:56 PM, Peng Liu wrote:
Hi all,
When I model a standard, I know the degeneracy through the other data. But for spectra of unknown material, I would like to set degeneracy as a variable like the amplitude, deltE0, e.g.. However, I can assign a letter to N and define it. Do you have any idea how I should do it?
Thanks for your reply,
Peng
-- Bruce Ravel ------------------------------------ bravel@bnl.gov National Institute of Standards and Technology Synchrotron Science Group at NSLS --- Beamlines U7A, X24A, X23A2 Building 535A Upton NY, 11973 Homepage: http://bruceravel.github.io/home/ Software: https://github.com/bruceravel Demeter: http://bruceravel.github.io/demeter/