On Monday 08 May 2006 08:47, you wrote:
I am a Ph.D. student in Gwangju Institute Science and Technology, South Korea. I have been tried to analyze my EXAFS sample with reference of As2O3 (arsenious oxide) obtained from "The Atoms.inp Archive (http://cars9.uchicago.edu/~newville/adb/search.html). But I could not run the feff in the Artemis (version 0.8.006) successfully with the As2O3 atoms file. Could you let me know how to solve the problem? It would be very honor to me if you let suggest a clue for the problem, sir.
Ji-Hoon, This is the sort of question that should be asked on the Ifeffit mailing list, so I am taking the liberty of CCing my answer there. I agree that the input file for As2O3 from the database is wrong. It generates an obviously incorrect list of coordinates. You need to go to the crystallography literature and find the correct data for that structure. There is nothing wrong (at least with respect to this question!) with Artemis. It seems likely that the problem is with the reliability of the data for As2O3 in the database. B -- Bruce Ravel ---------------------------------------------- bravel@anl.gov Molecular Environmental Science Group, Building 203, Room E-165 MRCAT, Sector 10, Advanced Photon Source, Building 433, Room B007 Argonne National Laboratory phone and voice mail: (1) 630 252 5033 Argonne IL 60439, USA fax: (1) 630 252 9793 My homepage: http://cars9.uchicago.edu/~ravel EXAFS software: http://cars9.uchicago.edu/~ravel/software/