On 03/08/2016 04:10 PM, lijuncha@msu.edu wrote:
Hi all,
During my use of Artemis, I found out that the FEEF paths finder had some problem with my atom, which is Cu12Sb4S13 in the attachment. I firstly ran atom on Cu12e, then ran the FEFF calculation. Then I found that the S24g.1 path was missing. Since S24g is near the core atom Cu12e and the path should exist, I was confused to send the message and hopefully get your response.
As I have said many times before, that's a feature, not a bug. http://bruceravel.github.io/demeter/artug/extended/fuzzy.html B -- Bruce Ravel ------------------------------------ bravel@bnl.gov National Institute of Standards and Technology Synchrotron Science Group at NSLS-II Building 535A Upton NY, 11973 Homepage: http://bruceravel.github.io/home/ Software: https://github.com/bruceravel Demeter: http://bruceravel.github.io/demeter/