Dear Hao: Just looking at your fit results, I noticed that enot_2 is also much too large at 35 eV and the dr_2 value is also quite large. Whay are you setting these parameters to such large values? Did you extract them from something else? Cheers, Carlo On Fri, 23 Feb 2007, hw26@njit.edu wrote:
Dear all,
I am doing model fitting using Artemis. My sample is uranium solution with an ionic liquid, 1-methoxyethyl-3-methyl imidazolium tetrafluoroborate (MOEMIMBF4). The Fitting seems ok except that the ss_2 is negative. I don't know how can I fix this problem. Can you get a chance to take a look? My fitting is simple, only three single scattering pathes which were produced by Six Pack. The fitting file is attached. I really appreciate it if you could take a look and give some advice!
Best regards! Hao
-- Carlo U. Segre -- Professor of Physics Associate Dean for Special Projects, Graduate College Illinois Institute of Technology Voice: 312.567.3498 Fax: 312.567.3494 segre@iit.edu http://www.iit.edu/~segre segre@debian.org