13 May
2013
13 May
'13
7:05 p.m.
On Monday, May 13, 2013 02:49:21 PM Bruce Ravel wrote:
The part that needs fixing is that, while Athena is rememberiong the column selection from the last time you imported a similar data file, it is not remembering the energy units. I am going to work on that this afternoon. Whenever I make a new release, this will be fixed.
Well, that didn't take long. Thanks, Atul, for discovering and reporting this bug. B -- Bruce Ravel ------------------------------------ bravel@bnl.gov National Institute of Standards and Technology Synchrotron Methods Group at NSLS --- Beamlines U7A, X24A, X23A2 Building 535A Upton NY, 11973 Homepage: http://xafs.org/BruceRavel Software: https://github.com/bruceravel