Athena does not handle that many columns gracefully. We use a Python program to split these data up into one file for each of the elements and then work from there. Carlo On Mon, 6 Oct 2003, Vivek S. Murthi wrote:
Hi Matt, Bruce..
Athena could not open files from NSLS beamline X10C vax machine which has data in the form of .XFS. So, I converted it to *.dat and made it look like a dat file from NSLS beamline X 11a. Athena doesnot give me any prompt for incompatability but it simply crashes and closes. The data I have is from a 13 element detector, so there are about 38 columns of data. I am not sure if this would make Athena crash. If So, do you have any suggestions to overcome this.
thnks vivek
Vivek S. Murthi Graduate Research Assistant 419 Egan Center Northeastern University Boston, MA-02115 Phone: 617-373-8949
_______________________________________________ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
-- Carlo U. Segre -- Professor of Physics Associate Dean for Special Projects, Graduate College Illinois Institute of Technology Voice: 312.567.3498 Fax: 312.567.3494 segre@agni.phys.iit.edu http://www.iit.edu/~segre