Thanks Stefan, The odd thing was because I saw slightly different things, I also imported the athena data to Larch directly to compared the plots but I think it might my own doing by changing the plot window parameters. Chris ********************************************** Dr Christopher Patridge Associate Professor Dept of Chemistry SASE 315 716-829-8096 | patridgc@dyc.edu www.dyc.edu http://www.dyc.edu/ Social: Twitter http://www.twitter.com/drpatridgc
On Oct 25, 2021, at 9:17 AM, Mangold, Stefan (IPS)
wrote: Dear Chris,
seen similar issues with Larch. The data (edge Jump 0.25), 200.k counts per channel. Used Fluorescence signal for Athena and Larch. Used the same parameter and got different result. Very similar to yours …
best regards
Stefan Mangold
Am 25.10.2021 um 14:41 schrieb Christopher Patridge
mailto:patridge@buffalo.edu>: Hello,
I am using Larch and Athena together and I just have a question about the magnitude plots and its effect (if any) on EXAFS modeling. Below are plots of the same merged samples using the same setting values. I noted that the plot in Larch begins below 0 and just want to make sure this is not a setting I missed in Larch?
Thank you,
Chris
********************************************** Dr Christopher Patridge Associate Professor Dept of Chemistry SASE 315 716-829-8096 | patridgc@dyc.edu mailto:patridgc@dyc.edu www.dyc.edu http://www.dyc.edu/
Social: Twitter http://www.twitter.com/drpatridgc
_______________________________________________ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov mailto:Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit
_______________________________________________ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit