On Wednesday, February 20, 2013 04:41:31 PM Bruce Ravel wrote:
but understand your concerns about the data I sent as they were just test files we collected when we were setting up the beam. However, I do not think the abridged range is the cause of the problem, as I wasl having issues importing real data as well (i.e. -150 eV pre-edge and k=12 post edge). These spectra files are attached, along with the error log file and the dathena.log file that was recorded when importing these files.
You are correct. When importing multiple data sets through the HXMA filetype plugin, the reference channels for all but the first file are imported incorrectly. I am not yet sure what is causing the problem, but I will look into it and try to have a solution in place for the next release.
Unfortunately, the only workaround entirely within Athena is to import the data one at a time.
As I look into this problem, and with some additional useful information from Fred Mosselmans, I see that this is a pervasive problem (and not specific to the HXMA plugin) that had somehow escaped my attention. Yikes! I have been working on this today. Hopefully, I will have a solution soon. B -- Bruce Ravel ------------------------------------ bravel@bnl.gov National Institute of Standards and Technology Synchrotron Methods Group at NSLS --- Beamlines U7A, X24A, X23A2 Building 535A Upton NY, 11973 Homepage: http://xafs.org/BruceRavel Software: https://github.com/bruceravel