On Friday 24 September 2004 03:52 pm, hsnuboy@ksu.edu wrote:
3. Sometimes, The results obtained from Artemis seems not the same. Says, the guess parameters and uncertainties may be varied even if you input the same data for different time.Has anyone met this problem before?
Yu-Chuan, I have seen this happen, but the situation was somewhat unusual. I would like to see a project file for which this happens reproducibly. B -- Bruce Ravel ----------------------------------- ravel@phys.washington.edu Code 6134, Building 3, Room 222 Naval Research Laboratory phone: (1) 202 767 2268 Washington DC 20375, USA fax: (1) 202 767 4642 NRL Synchrotron Radiation Consortium (NRL-SRC) Beamlines X11a, X11b, X23b National Synchrotron Light Source Brookhaven National Laboratory, Upton, NY 11973 My homepage: http://feff.phys.washington.edu/~ravel EXAFS software: http://feff.phys.washington.edu/~ravel/software/exafs/