Hi Bruce,
I checked and it shows that all the values are the same in both platforms.
Thanks.
Sincerely,
Shanshan Liu
----- Original Message -----
From: "Ravel, Bruce"
Hi Shanshan,
A few questions:
1. Are the normalization orders the same? (Click the Show additional parameters button in the background removal section to see that parameter.) 2. Are the values of spline clamps the same. (Also visible among the additional parameters.) 3. Are the numerical values associated with the spline clamps the same? (The values are set among the preferences. Look for the Clamp group on the preferences dialog.)
Another thing to look at is the contents of the Ifeffit buffer immediately after making those plots. Are there any obvious differences in the commands sent to Ifeffit on the two platforms?
B
-- Bruce Ravel ----------------------------------- bravel@bnl.gov
National Institute of Standards and Technology Synchrotron Methods Group at Brookhaven National Laboratory Building 535A Upton NY, 11973
My homepage: http://cars9.uchicago.edu/~ravel EXAFS software: http://cars9.uchicago.edu/~ravel/software/exafs/
-----Original Message----- From: ifeffit-bounces@millenia.cars.aps.anl.gov on behalf of Shanshan Liu Sent: Wed 12/12/2007 12:58 PM To: ifeffit@millenia.cars.aps.anl.gov Subject: [Ifeffit] different edge step by linux and window vista
Dear all,
It seems there is a problem when I use athena to open the file under the windows vista environment.
According to the specific scan channel, the data gave the big differentedge step by linux and windows.(Other parameters are similar), and the figures seem strange(I do not know what caused it). Now I am sending the screen-shot that I see. Please help me about that.
Thank a lot.
Shanshan Liu
BCPS Dept. Illinois Institute of Technology