Dear All
Firstly, I would like to say sorry if I have missed out on this discussion before but it would be great if you could help me out. I have been analyzing some Mn K-edge XAS data for some battery materials. While the XANES data shows no shift in the main absorption peak which means that there is no oxidation change happening, however, when I am fitting
Dear Dr Carlo
The edges are almost identical. The pre-edge intensity change isn't that
significant I feel. I did the Artemis fittings with the coordination
numbers fixed. Maybe I can try varying the coordination numbers and see if
it gives a different result.
I have attached the images of the pre-edge and main peak.
Thanks and Regards
Disha
From: Carlo Segre
data in Artemis, I can see a shift in the bond lengths suggesting an oxidation change. Is it possible that bond lengths change even though XANES spectra show no change?
Thank you and Kind Regards Disha
--
Carlo U. Segre -- Duchossois Leadership Professor of Physics
Interim Chair, Department of Chemistry
Director, Center for Synchrotron Radiation Research and Instrumentation
Illinois Institute of Technology
Voice: 312.567.3498 Fax: 312.567.3494
segre@iit.edu http://phys.iit.edu/~segre segre@debian.org
_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit
Disha Gupta
Graduate Student
School of Materials Science and Engineering
Nanyang Technological University (NTU), Singapore
+65 84087404
DISHA001@e.ntu.edu.sg
On Mon, Jun 11, 2018 at 11:34 AM, Disha Gupta
Dear All
Firstly, I would like to say sorry if I have missed out on this discussion before but it would be great if you could help me out. I have been analyzing some Mn K-edge XAS data for some battery materials. While the XANES data shows no shift in the main absorption peak which means that there is no oxidation change happening, however, when I am fitting the data in Artemis, I can see a shift in the bond lengths suggesting an oxidation change. Is it possible that bond lengths change even though XANES spectra show no change?
Thank you and Kind Regards Disha