Hi Renske, Thanks fo rthe report. I'll look into it. B On Friday 15 August 2008 05:56:23 van der Veen Renske wrote:
Hello!
I just downloaded the new version of Ifeffit (1.2.11) and I am happy with it except for a small bug that wasn't present in the previous version.
I am used to work with many different FEFF calculations for the same data set, all with the same fit model. I usually copy the path parameters from one calculation to all the others by using <right click> "Paths -> Export these path parameters... -> to SELECTED paths". Although a bit cumbersome for many paths and calculations, it worked fine in the previous version of Artemis. In the new version, it does exactly the opposite from what I want: it exports the path parameters to all the paths EXCEPT the ones I selected.
Is there a chance to fix this, or does anybody know a more cunning way to copy the path parameters from one calculation to the others on a path-by-path basis?
-- Bruce Ravel ------------------------------------ bravel@bnl.gov National Institute of Standards and Technology Synchrotron Methods Group at NSLS --- Beamlines U7A, X24A, X23A2 Building 535A Upton NY, 11973 My homepage: http://xafs.org/BruceRavel EXAFS software: http://cars9.uchicago.edu/~ravel/software/exafs/