Hi Eugenio,
Quick question: Did you change the tags for the Co atoms so that they are
different?
If I do that, I get 4 and 6 coordinate results. you can import the cif file
twice, run atoms on both
sites (with tags different) and get the two feff inputs for running.
-R.
On Thu, Apr 9, 2015 at 5:01 AM, Eugenio Paris
Hello everybody,
I'm trying to make Co K-edge EXAFS fitting for the Co3O4 compound (*.cif file is attached). The nearest neighbour of Co is oxigen at about 1.93 Angstrom distance. Cobalt sits in two inequivalent sites in the unit cell. When I perform the FEFF calculation in Artemis for either one or the other site i get the same path with Reff = 1.93 and degeneracy = 4. So i wonder what is the correct way to take account of the presence of both sites. At the beginning i was thinking to put 2*amp as S0^2 parameter to take account for twice the coordination number. Then i tried to use the "Aggregate" option in Artemis. When I use this option i get exactly the same result, i.e. a SS path with Reff = 1.92 and degeneracy = 4... I was expecting to get twice the degeneracy.. (the margin and beta parameters are set to default)
My question is: Why do i get the same path list when I do use the "Aggregate" pathfinder and when I don't? What is wrong in my interpretation?
Thank you in advance! Sincerely, Eugenio
_______________________________________________ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit