Dear all:
When I get a wrong fit about Mo-O and Mo-S fit of first two shells.
ssO = 0.00729812 # +/- 0.00961052 [0.00300]
delrO = -0.02968655 # +/- 0.03378397 [-0.05765]
enot = -5.30590978 # +/- 7.08310376 [-16.71557]
NO = -1.88450657 # +/- 1.59438947 [0.5]
NS = 1.71281926 # +/- 1.08552732 [1.00000]
delrS = 0.00418341 # +/- 0.04904499 [-0.05647]
ssS = 0.00329415 # +/- 0.00688491 [0.00300]
name N S02 sigma^2 e0 delr Reff R
==========================================================================
S1.1 1.000 1.456 0.00329 -5.306 0.00418 2.41350 2.41768
O7.1 1.000 -1.602 0.00730 -5.306 -0.02969 1.54660 1.51691
name ei third fourth
==========================================
S1.1 0.00000 0.00000 0.00000
O7.1 0.00000 0.00000 0.00000
ssO with a negative coordiantion number NO.I searched the mailist there is only information about negative ss
http://www.mail-archive.com/ifeffit%40millenia.cars.aps.anl.gov/msg02326.htm... ss to compensate small amp).but here I even get a negative amp.What's wrong can cause a negative amp?
Thanks for help.
Sincerely,
-----原始邮件-----
发件人: "ZHAN Fei"