the plot from researchgate is transmission data, your data is fluorescence;
best regards
Stefan Mangold
Am 01.07.2021 um 10:17 schrieb 田能全 mailto:tien.nengchuan@gmail.com>:
Hi Stefan,
Thanks for the response. I am confusing about the two plots. Could you please explain more about the difference?
https://www.researchgate.net/publication/231097049_Cs_L-edge_EXAFS_atomic_ab...
Kind regards,
N. C. Tien
Mangold, Stefan (IPS) mailto:stefan.mangold@kit.edu> 於 2021年7月1日 週四 下午3:38寫道:
normal for every element,
the higher the energy, the larger is the penetration depth —
regards
Stefan Mangold
Am 01.07.2021 um 06:13 schrieb 田能全 mailto:tien.nengchuan@gmail.com>:
Hi everyone,
My colleague sent me data of liquid CsNO3 sample measured using fluorescence model. According to the attached figure, I don't understand why mu(E) increased with increasing energy before and after the L3 edge. Does it make sense for cesium? Thanks.
Nengchuan