Dear Mingliang,
I have a book chapter that details how Athena normalizes data and LCF.
I'll send it to you if you want.
Just email me directly at dr.sdkelly@gmail.com. It is about 8 Meg so
make sure you have room in your mail box for it.
Cheers,
Shelly
2010/1/28 康明亮
Dear, I want to to ask a question about using Linear Combination Fitting in Athena. I normalized all the references(measured in transmission mode) and samples (fuorescence mode) with Athena, and then wish to use LCF to quantify each unique component in the samples. But I noted that the normalized samples spectra had lower height at the white line peak than any references(shown pic-1.emf in annex), thus the fitted spectra were also higher than the original sample spectra (shown pic-2 and -3.emf in annex). I do not know why? I also attached all the original data(before normalization). Wish to obtain guidance from you. Thanks! Best wishes Mingliang
________________________________ 网易邮箱,没有垃圾邮件的免费电子邮箱! _______________________________________________ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit