Dear all, It's true and precise your remark Fred. With Demeter 9.21, the Feff 8.2 is running properly in Demeter Atoms or well in Artemis, but at the moment to get the paths they are not present. But if you right click with the mouse, you can READ the geometry for the paths but with a error message : Demeter:UI:Artemi Error Couldn't retrieve information about list control item -1 ... from my eyes it seems to be something related with Demeter's pathfinder but I'm not an expert Anyway, also thanks Guanghui for your comments that help us to understand where is coming from this problematic. Could be great if in the future someone could find/propose a solution Kind regards Janeth On 10/06/2015 19:00, ifeffit-request@millenia.cars.aps.anl.gov wrote:
Send Ifeffit mailing list submissions to ifeffit@millenia.cars.aps.anl.gov
To subscribe or unsubscribe via the World Wide Web, visit http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit or, via email, send a message with subject or body 'help' to ifeffit-request@millenia.cars.aps.anl.gov
You can reach the person managing the list at ifeffit-owner@millenia.cars.aps.anl.gov
When replying, please edit your Subject line so it is more specific than "Re: Contents of Ifeffit digest..."
Today's Topics:
1. how to manage Demeter with a newer FEFF version ? (fred.mosselmans@diamond.ac.uk)
----------------------------------------------------------------------
Message: 1 Date: Wed, 10 Jun 2015 07:42:35 +0000 From:
To: Subject: [Ifeffit] how to manage Demeter with a newer FEFF version ? Message-ID: Content-Type: text/plain; charset=us-ascii Dear Janeth,
Feff8.5L (and presumably 8.4) works in some fashion in Demeter version 18.2 , in later versions it doesnt. : It runs through atoms and gives fits that seems sensible for transuranic elements in the times I and some of my collaborators have used it.
Thus in the short term if you want to use something higher than FEFF6 in your exafs calculations and want to use Demeter that's your option,
If you need to use FeFF9 and want to use Demeter: I think your best option is to have a go at persuading some of the software guys at your facility to collaborate with Bruce and Matt in adding a FEFF9 option to larch and in turn then Demeter.
Best wishes Fred
----------------------------------------------------------------------
Message: 1 Date: Mon, 08 Jun 2015 11:13:33 +0200 From: "M. Janeth LOZANO RODRIGUEZ"
To: ifeffit@millenia.cars.aps.anl.gov Subject: [Ifeffit] how to manage Demeter with a newer FEFF version ? Message-ID: <55755CBD.6010007@esrf.fr> Content-Type: text/plain; charset=utf-8; format=flowed Dear XAFS community,
I wondering about the availability to use a newer FEFF version in Demeter. Since my knowledge only I can run FEFF6. In my case I found different discrepancies using FEFF6 and FEFF9 in the determination of bond length distances for instance. In terms of review of papers, reviewers ask to use a newer version instead FEFF6. These points strongly suggest me coming back to the obsolete Athena/Artemis version.
On this obsolete version, you can download the paths generated by FEFF8, FEFF9. This issue is really useful when we have access to FEFF 9, for example. Is there any option to implement this nice feature in Demeter? Does anyone have an idea how to do it?
Kind regards Janeth Lozano
------------------------------
_______________________________________________ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
End of Ifeffit Digest, Vol 148, Issue 10 ****************************************