On 10/07/2014 10:48 PM, Paul Fons wrote:
If one outputs a standard (in this case for Fe) file from Hephaestus and attempts to read it in as an "xmu" file in athena, the following happens.
There is no such thing in Athena's column selection dialog as an "xmu" option. There is a "mu(E)" option and an "xmu.dat" option. The former is for XAS data with the expectation that it will betreated as EXAFS data (as opposed to the "xanes" option, which disables background removal for the data group). The latter is for the xmu.dat file that Feff writes out. That even made it into the document! http://bruceravel.github.io/demeter/aug/import/columns.html#datatypesandener... B -- Bruce Ravel ------------------------------------ bravel@bnl.gov National Institute of Standards and Technology Synchrotron Science Group at NSLS --- Beamlines U7A, X24A, X23A2 Building 535A Upton NY, 11973 Homepage: http://bruceravel.github.io/home/ Software: https://github.com/bruceravel Demeter: http://bruceravel.github.io/demeter/