Hi Bruce, Feel free to have them contact me. I have done a lot of Re compounds. Jeff Jeff Terry Biological, Chemical, and Physical Sciences Illinois Institute of Technology Chicago IL 60616 630-252-9708 On Dec 7, 2004, at 2:37 PM, Bruce Ravel wrote:
Hi,
Last week I was asked an interesting question. A long-time ifeffit user was showing A&A to some grad students new to the XAS biz:
[An] issue that came up with them as they began to use the software was: Dealing with background substraction from compounds with enormous white lines (Re data).
I thought it would be useful to hear comments from people on the mailing list. Any takers?
B
-- Bruce Ravel ----------------------------------- ravel@phys.washington.edu Code 6134, Building 3, Room 405 Naval Research Laboratory phone: (1) 202 767 2268 Washington DC 20375, USA fax: (1) 202 767 4642
NRL Synchrotron Radiation Consortium (NRL-SRC) Beamlines X11a, X11b, X23b National Synchrotron Light Source Brookhaven National Laboratory, Upton, NY 11973
My homepage: http://feff.phys.washington.edu/~ravel EXAFS software: http://feff.phys.washington.edu/~ravel/software/exafs/
_______________________________________________ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit