5 Dec
2006
5 Dec
'06
12:31 p.m.
Hi all, I did fits with self absorption corrected data (Fluo and Booth algorithms) and the value for S02 is 1.20 (0.30). It seems that I am not very lucky, if I take an average value (1.20 and 0.50), it should be ok (0.85) jeje, I am joking. Then...what can I do now? Thank you very much, Best regards, JA P.S. If I do not answer until Monday do not hate me, I will be on holidays.