Dear Mohamed, There is an example of CeO2 EXAFS analysis, taking into account background problems, in the following paper: *J. Padežnik Gomilšek, I. Kozjek-Škofic, N. Bukovec, A. Kodre */X-ray absorption study of CeO2 and Ce/V mixed oxide thin films obtained by sol-gel deposition. /* *Thin solid films, vol. 446, issue 1, (2004) 117-123. regards Iztok Arcon mohamed sobhy wrote:
Dear all I am trying to use artemis to do fitting to CeO2. But really I cant get the right way to do that. During the fitting, I am using amp as set and change in N degeneracy of the path. attached is the best fit i got but it still not good and the chi-square is 41.109065479 so can you suggest me what to do
thanks
Mohamed
------------------------------------------------------------------------
_______________________________________________ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
-- Iztok Arcon University of Nova Gorica Vipavska 13, POB 301 5001 Nova Gorica, Slovenia tel: +386 5 331 5227 fax: +386 5 331 5240 e-mail: iztok.arcon@ung.si http://www.ung.si/~arcon http://www.ung.si/~arcon/xas