Hello, I am having some issues when importing multiple data sets into Athena. When I try to import more than one file at a time only the reference sample data from the first file are imported and the subsequent files do not import the reference data (only a straight line is imported). There is an error that is reported, and I have saved the error log [log.txt] and attached it in the zip file (as well as the dathena.log file and some sample spectra files). The spectra files are of the Mo K-edge and the reference is an Mo foil. These spectra were collected using the HXMA beamline, and as such, I am using the HXMA plug-in to import the data. The relevant columns for the reference are: col 2: energy col 6: I1 col 7: I2 I searched the archive and found what I think is a similar issue (link: www.mail-archive.com/ifeffit@millenia.cars.aps.anl.gov/msg03454.html), and hope I'm not over-reporting the error (sorry in advance if I am), but the previous report seemed somewhat different, in that there was an issue with the wrong edge being chosen for the test and ref data (best I can tell). I do have the work around of importing each file individually, so this is no more than an inconvenience, but I thought I'd report it and see if maybe someone had some up with a more elegant solution. I am currently using version 9.14 on a 64-bit windows platform. Thanks in advance for any advice or help the community can provide! -- John Hayes The Grosvenor Group Dept. of Chemistry University of Saskatchewan Two fish are in a tank. One turns to the other and says, "You man the guns, I'll drive."