Abhijeet,
This is data from the Lytle database. The first thing you'll need to
do is to add '#' characters to the first column of the top several
lines of the data file (before the columns of real data start). But
that's still not enough, as Athena expects data to be in columns of
energy -- this data is not recorded by energy but by steps of the
monochromator rotation stage. You'll need to convert steps to degrees
and then to energy. See
http://cars9.uchicago.edu/ifeffit/FAQ/Data_Handling#head-e7e2389af58d378379f...
For more hints on how to handle this data file.
Cheers,
--Matt
2008/11/6 abhijeet gaur
I am doing my research work on EXAFS . For that I am using the software ATHENA for analyzing my data which my guide had brought from SSRL ( USA ) . But there is some problem in that , Athena is taking the data and plotting it but is not giving the required parameters. I am sending you the copy of that data . So if you can go through it and suggest me what is the problem , I wil be very thankfull .