Hi Zajac, What happens if you constrain all E0's to be the same? In the fit where they come out large, what are the uncertainties in the E0's? What are their correlations with other fitted parameters? There has been some debate in this list on the past as to how useful it is to allow for different E0's for different paths. It may be that Artemis is shifting the E0's for those paths in lieu of some other correlated parameter. --Scott Calvin Sarah Lawrence College On Jun 19, 2009, at 5:33 AM, Zajac, Dariusz A. wrote:
Hi all, can anybody help me and send some link about problems with enot in Artemis? in google, tutorials I couldn't find any help. Of course are few posts about delr or ss parameters, but enot is somehow omited (or I can not find it...)
the problem is with fiting K4W(CN)8*2H2O at W:L3 edge. fit and others parameters looks ok, except enot for C and N, where both are around 12 and don't want to fit to other values... thanks darek