FEFF: Broadening
> On Wed, 05 Jun 2002, Paula <pauhar@chem.gla.ac.uk> said:
P> Hello feffusers, I am investigating the system,
P> BaTiO3. Specifically l am looking at the elnes generated by the
P> xanes card. I would like to introduce broadening into my
P> calculation as it does not seem to converge, even for very big
P> clusters. If l increase Eimag for LDOS , (module two) will this be
P> carried through to the xanes calculation or is there another way
P> to introduce broadening? Also, if this is the correct way to
P> introduce broadening and get the calculation to converge with
P> smaller clusters, then what would be an appropriate value for
P> Eimag?
Paula,
You might try making the calculation with no additional broadening and
then use the CORRECTIONS keyword to convolve the final function with a
post facto broadening term.
B
--
Bruce Ravel ----------------------------------- ravel@phys.washington.edu
U.S. Naval Research Laboratory, Code 6134 phone: (1) 202 767 5947
Washington DC 20375, USA fax: (1) 202 767 1697
NRL Synchrotron Radiation Consortium (NRL-SRC)
Beamlines X11a, X11b, X23b, X24c, U4b
National Synchrotron Light Source
Brookhaven National Laboratory, Upton, NY 11973
My homepage: http://feff.phys.washington.edu/~ravel
EXAFS software: http://feff.phys.washington.edu/~ravel/software/exafs/