Many thanks Robert.

 

I was able to import everything after your suggestion.

 

About : “I don't like the steps in the original mu(E) either - rounding off too soon”

It’s because I have brutally rounded the data in excel. The initial data had 6 digits and I was wondering if it could be an issue for Athena.

 

Thanks again.

 

 

Best Regards,

Samy Ould-Chikh

 

KAUST Catalysis Center
Bldg.3,Level 4, #4231

4700 King Abdullah University of Science & Technology

Thuwal 23955-6900

Kingdom of Saudi Arabia

 

Tel: +966 12 8084486

E-mail: samy.ouldchikh@kaust.edu.sa

Website:  http://kcc.kaust.edu.sa/Pages/Home.aspx

 

 

 

 

 

 

From: Ifeffit [mailto:ifeffit-bounces@millenia.cars.aps.anl.gov] On Behalf Of Robert Gordon
Sent: Sunday, July 24, 2016 5:17 PM
To: ifeffit@millenia.cars.aps.anl.gov
Subject: Re: [Ifeffit] Bug Report importing file.

 

According to
http://millenia.cars.aps.anl.gov/pipermail/ifeffit/2013-August/006762.html
limit is 8192

It is possible to rebin the data in Athena...in multiple steps...what it first imports, then export, then
attach the missing higher E data, re-import, rebin...using a near edge step size of 0.2 eV, 0.05 invAng
in the EXAFS and 2 eV in the pre-edge, these two steps were sufficient to reduce the data size to 555 points.

The match between original and rebin does show some small differences but I didn't deglitch first.



I don't like the steps in the original mu(E) either - rounding off too soon,
or is it there at this level in the raw data?
...discrete noise/quantization error at the 1:800 level versus 'traditional exafs' 10^6 counts (1:1000)

On 7/24/2016 1:15 AM, Samy Ould-Chikh wrote:

Just a quick idea on why I cannot import the .txt file attached with previous email.
 
I realized that the files contain 11948 points ! (it's QEXAFS data).
Athena might have an hard limit of 8200 points that may be imported in a single file.
 
 
Best Regards,
Samy Ould-Chikh
 
KAUST Catalysis Center
Bldg.3,Level 4, #4231
4700 King Abdullah University of Science & Technology
Thuwal 23955-6900
Kingdom of Saudi Arabia
 
Tel: +966 12 8084486
E-mail: samy.ouldchikh@kaust.edu.sa
Website:  http://kcc.kaust.edu.sa/Pages/Home.aspx
 
 
 
 
 
-----Original Message-----
From: Samy Ould-Chikh
Sent: Sunday, July 24, 2016 10:56 AM
To: XAFS Analysis using Ifeffit <ifeffit@millenia.cars.aps.anl.gov>
Subject: Bug Report importing file.
 
Hello,
 
I have some issue to import a file in Athena: just a simple x-y column (.txt attached with this email).
 
Ti K-edge.
Data range in the file  : 4916.30 up to 5436.88 eV.
Issue: only data up to 5260 eV are imported (see screenshot: bug-importation).
 
Version: Demeter 0.9.24
System: Windows 7 Professional SP1
 
Well, I hope it's just not me not being able to find a proper way to import the file...
 
 
Best Regards,
Samy Ould-Chikh
 
KAUST Catalysis Center
Bldg.3,Level 4, #4231
4700 King Abdullah University of Science & Technology Thuwal 23955-6900 Kingdom of Saudi Arabia
 
Tel: +966 12 8084486
E-mail: samy.ouldchikh@kaust.edu.sa
Website:  http://kcc.kaust.edu.sa/Pages/Home.aspx
 
 
 
________________________________
 
This message and its contents including attachments are intended solely for the original recipient. If you are not the intended recipient or have received this message in error, please notify me immediately and delete this message from your computer system. Any unauthorized use or distribution is prohibited. Please consider the environment before printing this email.
 
_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit