Hi Chris, 

It looks to me like the y-axis is only showing 1 significant digit, which is a little strange.  (0 is shown 1, but "2" is shown 3 times) I don't think I've seen that.   Can you send data or a project that shows this?  

On Mon, Oct 25, 2021 at 7:41 AM Christopher Patridge <patridge@buffalo.edu> wrote:
Hello,

I am using Larch and Athena together and I just have a question about the magnitude plots and its effect (if any) on EXAFS modeling.  Below are plots of the same merged samples using the same setting values.  I noted that the plot in Larch begins below 0 and just want to make sure this is not a setting I missed in Larch?
  

Thank you,

Chris

**********************************************
Dr Christopher Patridge
Associate Professor 
Dept of Chemistry
SASE 315
716-829-8096 | patridgc@dyc.edu

Social: Twitter 


_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit


--
--Matt Newville