----- Original Message -----
Sent: Monday, May 28, 2007 7:51
PM
Subject: [Ifeffit] Low amp
results
I analyzed EXAFS spectra of trace of Fe
in lithium tantalate crystals. At first, I created the feff.inp file of
LiTaO3. Then I changed central Li atom to Fe atom and added Fe atom at
the Ta site. So that, the fitted results is good except amp(amp results is
0.3). I think that the model structure
is good, but I can not understand why amp is too low. How do you think about
this results? And, I tried to fitting treatment using GDS parameters. But, I
do not know that the general method how to use the GDS parameters. Please
tell me the general way of GDS manipulation. My PC runs under Win XP,
and My Artemis runs under feff8 conditions. Thank you.
Joji Kuniya
_______________________________________________
Ifeffit mailing
list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit