HI, Bruce and Matt
I have two questions for you,
please
help me.
1. I collected U EXAFS data on
APS 10-ID,
while I input a single data file with reference data in Athena,
it was
OK, however, when I input multiple data files (scans) also with
reference
data, it was crushed. I could input multiple data files without
reference
data, which Matt helped me trouble shoot. The Demeter 8.24
version is used
on my computer, I believe. Matt suggested me to update to the
current version.
I do not know if other users have this problem.
2. I have a U EXAFS data file
which
was collected at SSRL, however, I could not input this data file
using
Athena, how to fix this? format? See the attachment. thanks you
so much.
Dien Li, Ph.D.
Environmental Sciences and
Biotechnology
Savannah River National
Laboratory
Aiken, South Carolina, 29808
Tel: 803-725-7520
_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit