Richard,
 
I tried with Athena v50 and Artemis v007 and it worked (the data were ported correctly). I do not think it is version dependent.
 
The data that you save in Athena are ported to Artemis with 0 k-weighting, so you have to manually set your k-weighting in artemis if you want to match the same k-weighting that you liked in athena. As you know, there is k-weighting for FT and k-weigthting for plotting data in k-space, which have nothing to do with each other.
 
Note that the vertical axis in the bottom figure of your PDF file has unit of A^-3 which means it was indeed k2-weighting in FT in Artemis. You just have to make it k3 weighting in FT and it will give you the same plot as the top figure (and the unit will be A^-4).
 
Anatoly
-----Original Message-----
From: ifeffit-bounces@millenia.cars.aps.anl.gov [mailto:ifeffit-bounces@millenia.cars.aps.anl.gov] On Behalf Of Richard Mayes
Sent: Friday, November 09, 2007 12:13 PM
To: ifeffit@millenia.cars.aps.anl.gov
Subject: Re: [Ifeffit] SA and issue with importing into Artemis

Oops!  Forgot the attachments.  Sorry about that.

I should also add, the file I'm trying to import into Artemis is
"k_3.191_13.860".

-Richard


> Everyone, thanks for the info on self absorption!  I'm currently working
> on writing a short summary for our group based on the information everyone
> shared.
>
> Bruce, I'm having an issue importing a k3-weighted project into Artemis
> from Athena.  (I looked on the mail list and your webpage for a bug report
> and couldn't find one, my apologies if I missed it.)
>
> The problem:  I'm trying to import a k3-weighted spectrum into Artemis,
> but it appears to be importing the k2-weighted spectrum instead.  I don't
> know if this is related or a change between versions of Artemis, but the
> k-weight used in Athena isn't being carried over into Artemis as the fit
> k-weight as well.  Attached is the Athena and Artemis projects showing
> this and a pdf with pics of the 2 spectra I'm seeing (in case this is an
> issue only on my computer).  I tried changing the group name and deleting
> all the groups in Athena except the one I wanted and this still occurs.
>
> Any ideas on how to get around this?
>
> FYI:  I'm running Athena (0.8.054) and Artemis (0.8.011) on a laptop (1.7
> GHz Pentium M processor & 2 GB RAM) with Windows XP Pro.
>
> Thanks!!
> -Richard
>
> --
> Richard Mayes
>
> Barnes Group
> 450/452 Buehler Hall
> Department of Chemistry
> University of Tennessee
> Knoxville, TN 37996
>


--
Richard Mayes

Barnes Group
450/452 Buehler Hall
Department of Chemistry
University of Tennessee
Knoxville, TN 37996