Dear all,
I tried to import a data of multi-element detector at SPring-8 by using
plugin PFBL12C to Athena, but it was not successful.
if the number of rows in the file is about 2000[success.dat], it can be
successfully imported. But for the data over about 4000 rows[fail.dat],
it seems that several data at first of both converted energy and
intensity are substituted by 0. column6.png shows intensity of ch6 vs
energy_attained and I0.png shows intensity of I0 vs energy_attained. you
can see this behavior. As a result, intensity cannot divide by I0, and
data cannot be imported.
if someone knows approach to solve this, could you teach me.
Best regards,
Yuji Hiraoka
_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit