That's magnetite unfortunately!


On 12 August 2013 14:02, Scott Calvin <scalvin@sarahlawrence.edu> wrote:
Yes it does, Teck Kwang: http://millenia.cars.aps.anl.gov/cgi-bin/newville/Model-Search.cgi/ModelData/fe3o4_rt01_mar02.xmu

--Scott Calvin
Sarah Lawrence College

On Aug 11, 2013, at 11:12 PM, Teck Kwang Choo <teck.kwang.choo@monash.edu<mailto:teck.kwang.choo@monash.edu>> wrote:

The database: http://cars.uchicago.edu/~newville/ModelLib/search.html<http://cars.uchicago.edu/%7Enewville/ModelLib/search.html> does not seem to have Ferrite.

The matrix of my sample is largely Mg-ferrite where Fe is in the form of Fe (III). If you anyone has the spectra for Mg-ferrite, would it be possible to provide it to me? Otherwise, I do not think my sample spectra would be useable at all!

Thanks and kind regards.


On 10 August 2013 02:21, Matthew Marcus <mamarcus@lbl.gov<mailto:mamarcus@lbl.gov>> wrote:
I would guess that you need better standards.  In particular, FeO is not your typical Fe(II) mineral or oxide.  What is the system you're working on?
I have an extensive collection of Fe XANES reference spectra, including a number of Fe(II) species.

LCF gives you the fraction of Fe atoms included in the sample.  For example, suppose you had a sample which was genuinely a mix representable
as FeO.Fe2O3.  Then, LCF would properly report 2/3 Fe2O3 + 1/3 FeO because 2/3 of the Fe atoms are in the Fe2O3 fraction.
        mam


On 8/8/2013 8:37 PM, Teck Kwang Choo wrote:
Hello,

I have been using ATHENA to perform Linear Combination Fitting (LCF) on my XANES spectrum to quantify the amounts of Fe (II) and Fe (III) in my samples using only FeO and Fe2O3 as standards. The results showed a majority of Fe (II), which is contrary to what was expected.

This made me wonder if the LCF results from XANES is a molar percentage (mol %) or weight percentage (wt%).

Could anyone enlighten me on this matter?

Thanks!

--
Teck Kwang Choo
PhD Student
Department of Chemical Engineering
Room 225, Building 36
Monash University
Mobile No.: 04-11489904


_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov<mailto:Ifeffit@millenia.cars.aps.anl.gov>
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit

_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov<mailto:Ifeffit@millenia.cars.aps.anl.gov>
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit



--
Teck Kwang Choo
PhD Student
Department of Chemical Engineering
Room 225, Building 36
Monash University
Mobile No.: 04-11489904
_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov<mailto:Ifeffit@millenia.cars.aps.anl.gov>



--
Teck Kwang Choo
PhD Student
Department of Chemical Engineering
Room 225, Building 36
Monash University
Mobile No.: 04-11489904