Hi Matt and Bruce,
I request that Athena reports the uncertainty in the basic EXAFS parameters and not just the fitted variables. For example, the uncertainty in the optimized debye temperature is reported, but the uncertainty in sigma2 value is not currently reported. I could see how this could be done by Athena or by including a new function in IFEFFIT.
-What do you think?
Thanks
Shelly