Contd- Crystallographic input for a structure having screw axis and co-ordinates shifted by certain amount
Dear sir,
 herewith I am attaching two input files. The first one  with the name wyckoff .inp generates The first co-ordination sphere at 1.9465 angstrom with degenracy of 6. 
According to crystal structure data anatase structure should have 4 oxygens at 1.9339 angstrom and 2 oxygens at 1.9796 angstrom.  
So, I tried with the crystal input from the latest PDF-4+2013 database(attaching the PDF as word file for your ref. 
That (  inp file - attached)eventually generates the required co-ordination sphere with 4 oxygen at 1.3964( as against the XRD data of 1.9339) and 2 oxygen at 1.8925(aginst the XRD data from PDf-4+2013 of 1.9796 angstrom) 

Regards
Madhusmita Sahoo,
SO/C,TFCS/SND/MSG(22171)
Indira Gandhi Centre for Atomic Research,
Kalpakkam, Tamilnadu


On 13 June 2014 22:30, <ifeffit-request@millenia.cars.aps.anl.gov> wrote:
Send Ifeffit mailing list submissions to
        ifeffit@millenia.cars.aps.anl.gov

To subscribe or unsubscribe via the World Wide Web, visit
        http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
or, via email, send a message with subject or body 'help' to
        ifeffit-request@millenia.cars.aps.anl.gov

You can reach the person managing the list at
        ifeffit-owner@millenia.cars.aps.anl.gov

When replying, please edit your Subject line so it is more specific
than "Re: Contents of Ifeffit digest..."


Today's Topics:

   1. Re: Scattering paths in XANES calculations (Bruce Ravel)
   2. Re: Crystallographic input for a structure having screw axis
      and co-ordinates shifted by certain amount (Bruce Ravel)


----------------------------------------------------------------------

Message: 1
Date: Thu, 12 Jun 2014 15:42:22 -0400
From: Bruce Ravel <bravel@bnl.gov>
To: XAFS Analysis using Ifeffit <ifeffit@millenia.cars.aps.anl.gov>
Subject: Re: [Ifeffit] Scattering paths in XANES calculations
Message-ID: <539A029E.4050609@bnl.gov>
Content-Type: text/plain; charset=ISO-8859-1; format=flowed

On 06/12/2014 10:07 AM, Stefanie Roese wrote:
> But now I fail at getting the plots with the Energy at the x-axis and
> the normailzed mu at the y-axis likle Bruce did it in his talk. Which
> program was used there? Athena? And how can I get the
> energy/mu-information out of my feffnnn.dat files to compare to the
> total spectrum? I think I am quite close to the solution, but it does
> not work.

Stefanie,

The R-space figures were made using Artemis.  I fit the Fe foil data
using the version of Feff6 that comes with Artemis, then plotted the
data and the path relevant to each slide.

The energy plots were made using Athena back in the early days of Feff8
(which were also the early days of Athena!).  The plots show Fe foil
data and (if I remember correctly) column 4 of the xmu.dat file that was
one of the output files from Feff of that vintage.  I imported the data
and the xmu.dat file into Athena to make those plots.  The calculation
is offset downwards a bit using the y-axis offset in Athena.

To answer Matthew's question: interesting?  Not sure I'd go that far...!
  Here's the link:


https://speakerdeck.com/bruceravel/a-practical-introduction-to-multiple-scattering-theory

B



--
  Bruce Ravel  ------------------------------------ bravel@bnl.gov

  National Institute of Standards and Technology
  Synchrotron Science Group at NSLS --- Beamlines U7A, X24A, X23A2
  Building 535A
  Upton NY, 11973

  Homepage:    http://xafs.org/BruceRavel
  Software:    https://github.com/bruceravel


------------------------------

Message: 2
Date: Thu, 12 Jun 2014 15:49:56 -0400
From: Bruce Ravel <bravel@bnl.gov>
To: XAFS Analysis using Ifeffit <ifeffit@millenia.cars.aps.anl.gov>
Subject: Re: [Ifeffit] Crystallographic input for a structure having
        screw axis and co-ordinates shifted by certain amount
Message-ID: <539A0464.1090102@bnl.gov>
Content-Type: text/plain; charset=ISO-8859-1; format=flowed


Madhusmita,

Regarding the first question, I am not clear what the problem is.  I
grabbed the crystal data for anatase from Matt's website:

    http://cars9.uchicago.edu/atomsdb/TiO2-ana.inp

and imported it into Artemis.  I certainly don't know what the
interatomic distances for anatase should be off the top of my head, but
what Atoms produced from that input data certainly seems reasonable.  If
you think there is a problem, you are going to need to explain it in a
way that I can reproduce easily on my own computer.

Regarding the second question,  the vector specified in the box labeled
"Shift vector" will be added to each site *before* any calculation is made.

B

On 06/12/2014 01:45 AM, madhusmita sahoo wrote:
> Dear Members,
>
> I would like to know,
>
> *Q1)* If there is a screw axis in the system, like the anatase phase of
> TiO2, whose space group is I41/amd, how should I  enter that in the
> atoms for feff calculation. Kindly tell me which  is the correct way.
>
> When I entered 141(the space group number) and I41/amd, both generated
> separate set of atomic positions.
>
>   The older version of artemis, now the new one(latest version), both
> generates different set of atomic position with the same
> crystallographic input, i.e if I enter 141(or I41/amd) in place of space
> group and run atoms, it generates two different set of co-ordinates in
> Artemis 0.8.012 and in Demeter 0.9.18. Ideally this should be same.
>
> *Q2)* And when co-ordinates is shifted by certain amount, do we have to
>   enter that in the shift vector as well as while defining the (x y z)
>   of a particular site. Or I should just enter the shift vector and
>   define the co-ordinates at its usual position ( I feel this one is
> correct).
>
>   For example in anatase crystal structure  the co-ordinates are shifted
>   by (0,0.25,-0.125).
>
> So, the inputs can be
>
> For shift vector 0,0.25,-0.125 and in place of sites Ti(core) x=0, y=0,
> z= 0 and O (scatterer) x= 0, y=0, z=0.20806
>
> (Or) shift vector 0,0,0 and in place of sites Ti(core) x=0, y=0.25, z=
> -0.125 and O (scatterer)  x= 0, y=0.25, z=0.08160 Ideally
>
> both should  give the same result. But it gives different set of atomic
> positions.
>
> Even the same input in different version of artemis is yielding
>   different results(in Artemis 0.8.012 and in Demeter 0.9.18) .
>
>     I am confused about  how atoms work in artemis. I request you to
> elucidate the correct method.
>
> Warm wishes
>
> Madhusmita
>
> India
>
>
> _______________________________________________
> Ifeffit mailing list
> Ifeffit@millenia.cars.aps.anl.gov
> http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
>


--
  Bruce Ravel  ------------------------------------ bravel@bnl.gov

  National Institute of Standards and Technology
  Synchrotron Science Group at NSLS --- Beamlines U7A, X24A, X23A2
  Building 535A
  Upton NY, 11973

  Homepage:    http://xafs.org/BruceRavel
  Software:    https://github.com/bruceravel


------------------------------

_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit


End of Ifeffit Digest, Vol 136, Issue 11
****************************************