Hi Chris, Using the single-scattering and multiple-scattering paths that have the same scattering atoms is not double counting. In general, including all the paths from a Feff calculation is what you ought to do to account for all of the EXAFS.
ZjQcmQRYFpfptBannerStart
This Message Is From an External Sender
This message came from outside your organization.
ZjQcmQRYFpfptBannerEnd
Hi Chris,
Using the single-scattering and multiple-scattering paths that have the same scattering atoms is not double counting. In general, including all the paths from a Feff calculation is what you ought to do to account for all of the EXAFS. But many paths will have
weak contributions, and so can often be neglected.
It gets more tricky to avoid double-counting if you mix paths from multiple Feff calculations, but it sounds like that is not what you're doing.
Cheers,
--Matt
From: Ifeffit <ifeffit-bounces@millenia.cars.aps.anl.gov> on behalf of Chris Pollock <cjp227@cornell.edu>
Sent: Tuesday, April 2, 2024 6:18 PM
To: XAFS Analysis using Ifeffit <Ifeffit@millenia.cars.aps.anl.gov>
Subject: [Ifeffit] Imidazole multiple scattering in Artemis
This Message Is From an External Sender
This message came from outside your organization.
Hi everyone,
I've been using Artremis for quite a while, but have only recently come across a case where the inclusion of multiple scattering seems to be important for fitting some data and wanted to ask what is probably a super basic question
to make sure I don't mess anything up.
I've recently collected some data on a metalloenzyme with a quite histidine-rich active site and, since it's been shown previously that multiple scattering is important for fitting the longer range scattering for these types of
systems, I wanted to make sure I capture this in my Artemis fits. The data appear to show scattering contributions from N3, C2, and N1 in the imidazole ring, and FEFF seems to agree that those paths are the most important, though it calculates the MS intensity
to be significantly greater than the single scattering for the farther N (N1). So, my super naive question is: To include multiple scattering paths in the fits--say, the Fe-N3-N1 triangle--is it correct to include the Fe-N3-N1 multiple scattering path in
addition to the Fe-N3 and Fe-N1 single scattering paths, or would that effectively be double counting the farther nitrogen (N1)?
Thanks in advance!