Thanks. In this case, is the number of neibors equal to N * SO2 in the model result? 

Regards

HM

Bruce Ravel ะด:

> On Monday, August 20, 2012 09:02:28 PM Huaming Guo wrote:
>> I am using the (D)Artemis for EXAFS fitting. However, the "N" is set to be a
>> constant in the (D)Artemis. We can not set the variable for this parameter.
>> How can I do that if I model non crystalline samples using (D)Artemis?
>> Thanks a lot. 

> In Artemis, N is a pure number, but S02 can take a math expression.

> In the EXAFS equation, N and S02 are multiplied together.

> Thus, you might consider parameterizing the amplitude by setting N to
> 1 and putting all of the parameterization in the math expression for
> S02.

> B


> -- 

>  Bruce Ravel  ------------------------------------ bravel@bnl.gov

>  National Institute of Standards and Technology
>  Synchrotron Methods Group at NSLS --- Beamlines U7A, X24A, X23A2
>  Building 535A
>  Upton NY, 11973

>  Homepage:    http://xafs.org/BruceRavel
>  Software:    https://github.com/bruceravel
> _______________________________________________
> Ifeffit mailing list
> Ifeffit@millenia.cars.aps.anl.gov
> http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit