Hi everyone,

I'm somewhat new to EXAFS and this is my first question for the Ifeffit mailing list (which is a great source of information by the way).
I was reading the excellent paper: "Path degeneracy and EXAFS analysis of disordered materials" and I have a "simple" question to ask:
How do I get from table 1 to table 2?

Specifically, I think I know how to use fuzzy degeneracy in Artemis for the paths in one FEFF calculation, but in this case there are 3 sites for Ti, and that means 3 FEFF calculations (rigth?).

So how do I use fuzzy degeneracy for paths from different FEFF calculations?
And by the way, is it right if I imagine the material as having only 1 "fuzzy"/average site for Ti?

Thanks in advance

Juan


****************************** ****************************** ****************************** *********