Hi Dave,

I'm at the beamline today and will get back to you tomorrow off of the list since this is a rather pointed question at my book chapter.
Shelly



Sent from my Palm Pre on the Now Network from Sprint


On Jun 23, 2011 9:15 AM, Dave <davidmorse00@gmail.com> wrote:

Hi list,
Doing my first steps in your world, I am trying to model my data.
I am following Kelly's helpful review from 2008 and stuck on apparently simple
issue:
In order to reduce my deltaE0 (now 9.2), following her advise, I am trying to
recall the theoretical spectrum from Artemis to Athena; this was produced by
filtering and fitting my data according to the first shell, then fixing all
parameters to their best fit, except for enot set to zero, making a sum of all
paths under these conditions, saving it as a chi(k) and take it to Athena. Here,
to my understanding, I suppose to introduce the 'new-made' chi(k) as a standard
and align my data accordingly, save it as a chi(k) and take it back to Artemis
to complete the fitting. Unfortunately I cannot make it a standard in Athena,
since the whole background options are not available when a chi file is called
in.
Can someone give a hint? Suggest other ways to better choose E0?

Best,
Dave

_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit