Thanks, got it. Some times OriginPro don't import the text files with header text properly.
 
Regards,
/Shoaib  


On Wed, Oct 2, 2013 at 10:19 PM, Bruce Ravel <bruceravel1@gmail.com> wrote:
On 10/01/2013 10:28 PM, Shoaib Muhammad wrote:
I have Mn XAS data and I am trying to export this XAS data by using
"File", "Save marked group as" and "norm E". My Mn XAS data shows some
spikes around 7150eV other than main Mn K edge peak due to some Fe
impurity. So it is hard to fit post edge and I have ticked "Flatten
normalized data" to get a straight line post edge. After doing this I
can see an almost straight line post edge in the Athena preview graph
but when I export ASCII data to plot in OriginPro etc it seems like data
is being exported with out "Flatten normalized data".
I have attached relevant information. Am I missing some point or is it a
software bug?

Which column in the norm(E) output file are you using in the plot?  That file has columns for both the normalized and the flattened spectra. Looks to me like you might be using the normalized column.

B


--
 Bruce Ravel  --------------------- bruceravel1@gmail.com

 Homepage:    http://xafs.org/BruceRavel
 Software:    https://github.com/bruceravel
_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit



--
Shoaib